      Description

      obs_test Camera has an incorrect focal plane to field angle transform and the distortion coefficient is incorrectly labeled. The radial coefficients describe field angle to focal plane, and the C3 term is in 1/rad^2. Fix this and provide a unit test in obs_base that sanity-checks the plate scale by converting focal plane to field angle near 0,0 and comparing against the known camera plate scale.