      Description

      When the crosstalk correction code was moved to above CCD assembly the routine extractAmp was changed to work on un-assembled CCDs.  This broke measureCrosstalk (this is hard to fix nicely until DM-15409 is resolved).

      Additionally, measureCrosstalk assumes that you have enough data to constrain all the crosstalk coefficients, and has no way to write the outputs.  Please fix these while you have the package open.