Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-16377

Reference catalogs with fluxSchema errors can't be loaded

    Details

    • Type: Story
    • Status: Invalid
    • Resolution: Done
    • Fix Version/s: None
    • Component/s: afw
    • Labels:
      None
    • Templates:
    • Story Points:
      1
    • Team:
      Data Release Production

      Description

      Dominique Boutigny reports that he's found a reference catalog with fluxSigma errors that can no longer be read by our code in w_2018_39 and later.

      How to reproduce:

       

      import lsst.meas.algorithms
       
      keys = lsst.meas.algorithms.getRefFluxKeys(ref.schema, 'lsst_u_smeared')
       
      assert keys[1] is not None 
      
      

      I suspect new backwards-compatibility code for flux to instFlux broke older backwards-compatiblity code for Sigma to Err.

        Attachments

          Container Issues

            Activity

              People

              • Assignee:
                jbosch Jim Bosch
                Reporter:
                jbosch Jim Bosch
                Watchers:
                Dominique Boutigny, Jim Bosch, John Parejko, John Swinbank
              • Votes:
                0 Vote for this issue
                Watchers:
                4 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved:

                  Summary Panel