Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-16696

PhotoCalib produces negative flux errors for negative flux measurements.

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Done
    • Resolution: Done
    • Fix Version/s: None
    • Component/s: afw

      Description

      The `PhotoCalib`, `instFluxToMaggies` method is missing an absolute value causing calibrated flux errors to be negative when fluxes are negative (as can happen in a difference image).