    Description

      DM-15862 broke y-band stray-light calibration lookup in Gen2 (which has always been a hack) by hard-coding a path, then deferring a fix for that to DM-16805.

      That more complete fix will still have to wait for that ticket, but I'll try to get a fix for Gen2 only done here.

       

      Attachments

        Issue Links

          Activity

            jbosch Jim Bosch added a comment - - edited

            czw, mind taking a look at this?  I think it probably breaks Gen3 even more than it was already broken, but fixes Gen2, and I think it gives us a path for fixing Gen3 on DM-16805 (I'll go comment there on what I think that would entail).

            jbosch Jim Bosch added a comment - - edited czw , mind taking a look at this?  I think it probably breaks Gen3 even more than it was already broken, but fixes Gen2, and I think it gives us a path for fixing Gen3 on DM-16805 (I'll go comment there on what I think that would entail).

            I agree that this likely gives the best path forward for fixing gen3.  Looks like a good solution to me.

            czw Christopher Waters added a comment - I agree that this likely gives the best path forward for fixing gen3.  Looks like a good solution to me.