      Description

      The metadata checking code that runs during read of curated calibrations from obs_x_data packages incorrectly assumes that CALIBDATE should match the validity start. It turns out that CALIBDATE is meant to be a label for the calibration and is distinct from validity. Please remove the check that requires them to match.