Details
-
Type:
Story
-
Status: Invalid
-
Resolution: Done
-
Fix Version/s: None
-
Component/s: ts_main_telescope
-
Story Points:0
-
Epic Link:
-
Sprint:TSSW Sprint - Apr 26 - May 10
-
Team:Telescope and Site
-
Urgent?:No
Description
It would be helpful to have a timestamp field added to the telemetry struct output by the low-level MT Rotator controller. My preferred format is that used by SAL: TAI unix seconds as double precision (float isn't accurate enough).
This would provide a reference point for reported velocity.
It would also allow computing a measured rotator velocity using (pos1 - pos0) /( t1 - t0) – which seems likely to avoid the oddities we see in the two actual velocities that are presently being reported.
I assume the low-level Rotator controller has easy access to TAI time; it certainly should, as it is necessary in order to properly handle tracking commands.
Attachments
Issue Links
Activity
Epic Link |
|
Labels | HexRot MainTelescope ccw-rotator-integration-test |
End date | 29/Apr/21 | |
Sprint | TSSW Sprint - Apr 26 - May 10 [ 1091 ] | |
Start date | 28/Apr/21 | |
Story Points | 1 |
Status | To Do [ 10001 ] | In Progress [ 3 ] |
Status | In Progress [ 3 ] | To Do [ 10001 ] |
Resolution | Done [ 10000 ] | |
Status | To Do [ 10001 ] | Invalid [ 11005 ] |
Story Points | 1 | 0 |