Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-26382

Please add a timestamp to the telemetry published by the Rotator low-level controller

    XMLWordPrintable

    Details

      Description

      It would be helpful to have a timestamp field added to the telemetry struct output by the low-level MT Rotator controller. My preferred format is that used by SAL: TAI unix seconds as double precision (float isn't accurate enough).

      This would provide a reference point for reported velocity.

      It would also allow computing a measured rotator velocity using (pos1 - pos0) /( t1 - t0) – which seems likely to avoid the oddities we see in the two actual velocities that are presently being reported.

      I assume the low-level Rotator controller has easy access to TAI time; it certainly should, as it is necessary in order to properly handle tracking commands.