Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-28087

obs_lsst accounts for detectors twice in IDs

    XMLWordPrintable

Details

    • Bug
    • Status: Done
    • Resolution: Done
    • None
    • obs_lsst
    • None
    • Architecture
    • No

    Description

      https://github.com/lsst/obs_lsst/blob/master/python/lsst/obs/lsst/_instrument.py#L117-L128 uses the max_detector_exposure_id as the maximum value of the visit and observation dimensions. But those maximums are later multiplied again by the maximum detector count. I believe the max_exposure_id should be used instead.

      Attachments

        Activity

          People

            ktl Kian-Tat Lim
            ktl Kian-Tat Lim
            Jim Bosch
            Jim Bosch, Kian-Tat Lim, Tim Jenness
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved:

              Jenkins

                No builds found.