Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-28936

Try to get calibration source selection consistent between gen2 and gen3 middleware

    XMLWordPrintable

    Details

    • Story Points:
      8
    • Epic Link:
    • Sprint:
      DRP S21a (Dec Jan)
    • Team:
      Data Release Production
    • Urgent?:
      No

      Description

      A detailed comparison between gen2 and gen3 middleware data products up to and including Single Frame Processing was made on DM-28858. It was revealed there that there are small differences in the sources that actually get used in the photometric and astrometric calibrations of order a-few-to-a-dozen per CCD. This leads to small differences in the WCS solutions resulting in slightly different CCD pixel scales (up to ~0.08 mas), coordinate offsets (up to ~3.4 mas), and small differences in some photoCalibs (differences up to: calibrationMean: 2e-03 calibrationErr: 6e-07 instFluxAtZeroMagnitude: 1e+09). Since we are so close to bitwise parity up to this point, it would be really nice to get all the way there (especially considering the desire to feed exactly the same inputs to both middleware versions of the fgcm and jointcal external calibrations).  An attempt to match up the selection of sources used in the SFP photometric and astrometric solutions between the two middleware versions will be attempted here.

        Attachments

          Issue Links

            Activity

              People

              Assignee:
              lauren Lauren MacArthur
              Reporter:
              lauren Lauren MacArthur
              Reviewers:
              Nate Lust
              Watchers:
              Jim Bosch, Lauren MacArthur, Nate Lust
              Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved:

                  Jenkins

                  No builds found.