Big red PANIC button in M1M3 gui, fault command

    XMLWordPrintable

    Details

    • Type: Improvement
    • Status: Done
    • Resolution: Done
    • Fix Version/s: None
    • Component/s: ts_main_telescope
    • Labels:

      Description

      Add a big red PANIC! button to M1M3 GUI/EUI. That will trigger mirror fault, leading to mirror to rest on statics support. This will help in situations when we notice something wrong is happening and would like to drive M1M3 to static support safety as soon as possible.

        Attachments

          Issue Links

            Activity

            Hide
            pkubanek Petr Kubanek added a comment -

            It's red, and it works while raising or lowering the mirror:

             

            Show
            pkubanek Petr Kubanek added a comment - It's red, and it works while raising or lowering the mirror:  
            Show
            pkubanek Petr Kubanek added a comment - Please see PRs: https://github.com/lsst-ts/ts_xml/pull/524 https://github.com/lsst-ts/ts_cRIOpy/pull/17 https://github.com/lsst-ts/ts_m1m3support/pull/83
            Hide
            dmills Dave Mills added a comment -

            lgtm

            Show
            dmills Dave Mills added a comment - lgtm
            Hide
            dneill Doug Neill added a comment -

            Petr

            You wrote that the panic button works when raising and lowering the mirror. Does it also work in engineer more, normal operations, etc?

             

            Doug

             

             

             

            Show
            dneill Doug Neill added a comment - Petr You wrote that the panic button works when raising and lowering the mirror. Does it also work in engineer more, normal operations, etc?   Doug      
            Hide
            pkubanek Petr Kubanek added a comment -

            Yes. Panic button works in all modes except when configuration isn't loaded (in Standby mode). Engineering, no-Engineering makes no difference - it still works and shall work.

            Show
            pkubanek Petr Kubanek added a comment - Yes. Panic button works in all modes except when configuration isn't loaded (in Standby mode). Engineering, no-Engineering makes no difference - it still works and shall work.

              People

              Assignee:
              pkubanek Petr Kubanek
              Reporter:
              pkubanek Petr Kubanek
              Reviewers:
              Dave Mills, Doug Neill, Te-Wei Tsai
              Watchers:
              Dave Mills, Doug Neill, Petr Kubanek, Roberto Tighe, Sandrine Thomas, Te-Wei Tsai
              Votes:
              0 Vote for this issue
              Watchers:
              6 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved:

                  Jenkins

                  No builds found.