Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-32989

Correct Cam HexRot ESS temperature sensor locations

    XMLWordPrintable

    Details

    • Type: Story
    • Status: Done
    • Resolution: Done
    • Fix Version/s: None
    • Component/s: None
    • Labels:

      Description

      The locations for the Camera HexRot temperature sensors were stated incorrectly at the Confluence page and in ts_config_ocs. This ticket is for correcting that.

        Attachments

          Activity

          Show
          wvreeven Wouter van Reeven added a comment - Fixed in https://confluence.lsstcorp.org/display/LTS/ESS+CSC+Index+Registry  
          Hide
          wvreeven Wouter van Reeven added a comment -
          Show
          wvreeven Wouter van Reeven added a comment - ts_config_ocs PR: https://github.com/lsst-ts/ts_config_ocs/pull/52  
          Hide
          rowen Russell Owen added a comment -

          Looks great! I also updated a Watcher ESS-based rule (camera hexapod over-temperature) to match your changes. Please check my work before merging.

          Show
          rowen Russell Owen added a comment - Looks great! I also updated a Watcher ESS-based rule (camera hexapod over-temperature) to match your changes. Please check my work before merging.

            People

            Assignee:
            wvreeven Wouter van Reeven
            Reporter:
            wvreeven Wouter van Reeven
            Reviewers:
            Russell Owen
            Watchers:
            Russell Owen, Wouter van Reeven
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Jenkins

                No builds found.