Install the LabVIEW RT OS

    XMLWordPrintable

    Details

    • Type: Story
    • Status: Done
    • Resolution: Done
    • Fix Version/s: None
    • Component/s: ts_main_telescope
    • Labels:
    • Story Points:
      2
    • Sprint:
      TSSW Sprint - Jan 03 - Jan 17
    • Team:
      Telescope and Site
    • Urgent?:
      No

      Description

      Install the LabVIEW RT OS on PXI-PC2, which is in the base data center. This will need the USB from Eric, which has the LabVIEW RT OS inside. I also need to work with IT for this.

      This is the reference provided by Eric: Converting a Desktop PC to a Phar Lap ETS Real-Time Target.

      For the requirement of desktop PC, follow Requirements for Desktop PCs as Phar Lap ETS Real-Time Targets.

      For the installation steps, follow:
      1. PC Compatibility with LabVIEW Real-Time or LabWindows/CVI Real-Time for Desktop ETS
      2. Using Desktop PCs as RT Targets with the Real Time Module.pdf

        Attachments

        1. fail_1.jpg
          fail_1.jpg
          2.26 MB
        2. fail_2.jpg
          fail_2.jpg
          2.13 MB
        3. fanFailInPC1.jpg
          fanFailInPC1.jpg
          1.81 MB
        4. Format.jpg
          Format.jpg
          2.17 MB
        5. NeedSoftware.jpg
          NeedSoftware.jpg
          1.96 MB
        6. NIMAX_PXI_PC1.png
          NIMAX_PXI_PC1.png
          46 kB
        7. NIMAX_PXI_PC2.png
          NIMAX_PXI_PC2.png
          42 kB
        8. PXI-PC1 PXI card.jpg
          PXI-PC1 PXI card.jpg
          3.81 MB
        9. usbInSpeedgoat.jpg
          usbInSpeedgoat.jpg
          87 kB
        10. Using Desktop PCs as RT Targets with the Real Time Module.pdf
          109 kB

          Activity

          Hide
          ttsai Te-Wei Tsai added a comment -

          Eric Coughlin, please help to answer the following questions in my mind. And if I lost anything, please help to comment as well. Thanks!

          1. What files do we have in the PXI-PC2 and do we need to backup the files? This is because the installation of LabVIEW RT OS will format the desktop PC to FAT32.

          2. What are the hardware specs of PXI-PC2 and are they compatible with the RT OS? Do we need to remove any PXI card to avoid the resource conflicts?

          3. Is the USB prepared by NI MAX and have the ability to reboot, format, and install the RT OS?

          4. Should we keep the USB to PXI-PC2 after rebooting with safe-mode or we need to try to install the Real-time module to let the desktop PC can reboot itself from hard-disk? If so, can we do this by NI MAX?

          5. It looks like we need to use the NI MAX to set the IP address of this PXI-PC2. Is this correct?

          Show
          ttsai Te-Wei Tsai added a comment - Eric Coughlin , please help to answer the following questions in my mind. And if I lost anything, please help to comment as well. Thanks! 1. What files do we have in the PXI-PC2 and do we need to backup the files? This is because the installation of LabVIEW RT OS will format the desktop PC to FAT32. 2. What are the hardware specs of PXI-PC2 and are they compatible with the RT OS? Do we need to remove any PXI card to avoid the resource conflicts? 3. Is the USB prepared by NI MAX and have the ability to reboot, format, and install the RT OS? 4. Should we keep the USB to PXI-PC2 after rebooting with safe-mode or we need to try to install the Real-time module to let the desktop PC can reboot itself from hard-disk? If so, can we do this by NI MAX? 5. It looks like we need to use the NI MAX to set the IP address of this PXI-PC2. Is this correct?
          Hide
          ecoughlin Eric Coughlin added a comment - - edited
          1. A windows install and no.
          2. Compatable with RT OS, you only need to remove 1 PXI ethernet card and move to PXI-PC1
          3. Yes.
          4. NI-Max is installed on the windows VM tma-windows.ls.lsst.org and will be used to provision the PXI controller. This means that once the USB is used to install Phar lap, I think it can be removed after the reboot that occurs.
          5. Yes, I believe that is correct.
          Show
          ecoughlin Eric Coughlin added a comment - - edited A windows install and no. Compatable with RT OS, you only need to remove 1 PXI ethernet card and move to PXI-PC1 Yes. NI-Max is installed on the windows VM tma-windows.ls.lsst.org and will be used to provision the PXI controller. This means that once the USB is used to install Phar lap, I think it can be removed after the reboot that occurs. Yes, I believe that is correct.
          Hide
          ecoughlin Eric Coughlin added a comment -

          As part of this ticket
          1. Find a flash drive and make it available to the Windows VM
          2. I then run the speedgoat kernel transfer tool to write to the flash drive.
          3. Then plug in the written drive to the speedgoat.

          Show
          ecoughlin Eric Coughlin added a comment - As part of this ticket 1. Find a flash drive and make it available to the Windows VM 2. I then run the speedgoat kernel transfer tool to write to the flash drive. 3. Then plug in the written drive to the speedgoat.
          Hide
          ecoughlin Eric Coughlin added a comment -

          4. Reboot the speedgoat and wait for the kernel transfer to complete.
          5. Then unplug the usb and the speedgoat will reboot into the updated kernel.

          Show
          ecoughlin Eric Coughlin added a comment - 4. Reboot the speedgoat and wait for the kernel transfer to complete. 5. Then unplug the usb and the speedgoat will reboot into the updated kernel.
          Hide
          ttsai Te-Wei Tsai added a comment - - edited

          The speedgoat is the white machine on the top shelf in the same cabinet. There is no account and password. Its IP address is tma-windows.ls.lsst.org.

          Show
          ttsai Te-Wei Tsai added a comment - - edited The speedgoat is the white machine on the top shelf in the same cabinet. There is no account and password. Its IP address is tma-windows.ls.lsst.org .
          Hide
          ecoughlin Eric Coughlin added a comment -
          Show
          ecoughlin Eric Coughlin added a comment - Windows VM is tma-windows.ls.lsst.org
          Hide
          ttsai Te-Wei Tsai added a comment -

          We will need IT to help setup a Windows VM for this flash drive to use. Eric will need it to run the transfer tool.

          Show
          ttsai Te-Wei Tsai added a comment - We will need IT to help setup a Windows VM for this flash drive to use. Eric will need it to run the transfer tool.
          Hide
          ecoughlin Eric Coughlin added a comment -

          Specifically the tma-windows VM needs to see the flash drive.

          Show
          ecoughlin Eric Coughlin added a comment - Specifically the tma-windows VM needs to see the flash drive.
          Hide
          ttsai Te-Wei Tsai added a comment - - edited

          We put the one of PXI card from PXI-PC2 to PXI-PC1 (see the red circle):

          Show
          ttsai Te-Wei Tsai added a comment - - edited We put the one of PXI card from PXI-PC2 to PXI-PC1 (see the red circle):
          Hide
          ttsai Te-Wei Tsai added a comment - - edited

          We tried the options of "Boot using software installed on the hard-disk" and "format". None of them worked for the following errors:

          I also tried to use my own USB (with the NI MAX to install the real-time OS), and it did not work as well.

          Hernan found the following references:
          1. Unable to Find Boot Program Ph_exec.exe in Real-Time Target
          2. How to Restore LabVIEW RT Target to Factory Default Configuration

          Show
          ttsai Te-Wei Tsai added a comment - - edited We tried the options of "Boot using software installed on the hard-disk" and "format". None of them worked for the following errors: I also tried to use my own USB (with the NI MAX to install the real-time OS), and it did not work as well. Hernan found the following references: 1. Unable to Find Boot Program Ph_exec.exe in Real-Time Target 2. How to Restore LabVIEW RT Target to Factory Default Configuration
          Hide
          ecoughlin Eric Coughlin added a comment -

          Is this PXI-PC1 or PC2?

          Show
          ecoughlin Eric Coughlin added a comment - Is this PXI-PC1 or PC2?
          Hide
          ttsai Te-Wei Tsai added a comment -

          Reformat the system and it will ask for the setup of network and installation of software (real-time target software):

          The system rebooted by itself and ask for the installation of real-time target:

          Show
          ttsai Te-Wei Tsai added a comment - Reformat the system and it will ask for the setup of network and installation of software (real-time target software): The system rebooted by itself and ask for the installation of real-time target:
          Hide
          ttsai Te-Wei Tsai added a comment -

          The PXI-PC2 sets the network configuration to have the IP of 169.254.52.143. But I do not understand why I can not ping it. I thought I am in the control network. I used the VPN as well. Do I need to use the NI MAX to reset the static IP?

          Show
          ttsai Te-Wei Tsai added a comment - The PXI-PC2 sets the network configuration to have the IP of 169.254.52.143 . But I do not understand why I can not ping  it. I thought I am in the control network. I used the VPN as well. Do I need to use the NI MAX to reset the static IP?
          Hide
          ttsai Te-Wei Tsai added a comment -

          I think based on Unable to Find Boot Program Ph_exec.exe in Real-Time Target, I am in the correct condition that the system was formatted. Check with Eric what else he wants.

          The PXI-PC2 is reformatted to the LabVIEW real-time OS and can reboot itself (by hard disk) to the safe mode if no software is installed.

          Show
          ttsai Te-Wei Tsai added a comment - I think based on  Unable to Find Boot Program Ph_exec.exe in Real-Time Target , I am in the correct condition that the system was formatted. Check with Eric what else he wants. The PXI-PC2 is reformatted to the LabVIEW real-time OS and can reboot itself (by hard disk) to the safe mode if no software is installed.
          Hide
          ttsai Te-Wei Tsai added a comment - - edited

          Put Eric's USB into the speedgoat:

          Show
          ttsai Te-Wei Tsai added a comment - - edited Put Eric's USB into the speedgoat:
          Hide
          ttsai Te-Wei Tsai added a comment -

          We need to put the USB to the machine of windows 10 instead to let Eric to format and install the software to it.

          Show
          ttsai Te-Wei Tsai added a comment - We need to put the USB to the machine of windows 10 instead to let Eric to format and install the software to it.
          Hide
          ttsai Te-Wei Tsai added a comment -

          Need to make sure I could use the NI MAX to see two machines and let Eric know to deploy the related software.

          Show
          ttsai Te-Wei Tsai added a comment - Need to make sure I could use the NI MAX to see two machines and let Eric know to deploy the related software.
          Hide
          ttsai Te-Wei Tsai added a comment - - edited

          I installed the software to the PXI-PC2 and set the IP to be 139.229.145.230. We rebooted it and make sure this value is persistent:

          Show
          ttsai Te-Wei Tsai added a comment - - edited I installed the software to the PXI-PC2 and set the IP to be 139.229.145.230 . We rebooted it and make sure this value is persistent:
          Hide
          ttsai Te-Wei Tsai added a comment -

          Fan in PXI-PC1 has the failure all the time:

          Show
          ttsai Te-Wei Tsai added a comment - Fan in PXI-PC1 has the failure all the time:
          Hide
          ttsai Te-Wei Tsai added a comment -

          I installed the software to the PXI-PC1 and set the IP to be 139.229.145.231:

          Show
          ttsai Te-Wei Tsai added a comment - I installed the software to the PXI-PC1 and set the IP to be 139.229.145.231 :
          Hide
          ttsai Te-Wei Tsai added a comment -

          PXI-PC1
          Name in NI MAX: NI-GenericDesktopPC-B3655747
          IP: 139.229.145.231

          PXI-PC2
          Name in NI MAX: NI-GenericDesktopPC-21111363
          IP: 139.229.145.230

          Show
          ttsai Te-Wei Tsai added a comment - PXI-PC1 Name in NI MAX: NI-GenericDesktopPC-B3655747 IP: 139.229.145.231 PXI-PC2 Name in NI MAX: NI-GenericDesktopPC-21111363 IP: 139.229.145.230
          Hide
          ttsai Te-Wei Tsai added a comment -

          Both of PXI desktop PCs had installed the LabVIEW real-time OS and can be reached from the NI-MAX from LSST-WAP (or VPN) now. Please see the comments for the IP and detailed information. Thanks!

          Show
          ttsai Te-Wei Tsai added a comment - Both of PXI desktop PCs had installed the LabVIEW real-time OS and can be reached from the NI-MAX from LSST-WAP (or VPN) now. Please see the comments for the IP and detailed information. Thanks!
          Hide
          ecoughlin Eric Coughlin added a comment -

          Work is complete and looks good on my end.

          Show
          ecoughlin Eric Coughlin added a comment - Work is complete and looks good on my end.