Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-34529

Rewrite the PDOs Mapping in Rotator Controller

    XMLWordPrintable

    Details

      Description

      Rewrite the PDOs mapping in rotator controller. Right now, the MOOG developers used the 0x2240 instead of 0x6064 in the fixed PDO: 0x1B00 and 0x1B40, which is not allowed. However, there is the servo frequency requirement in the Simulink model calculation, and we do need to use the 0x2240 for the drive configuration. Therefore, we could not use the non-fixed PODs instead as an easy solution. Instead, to fix this, the overhaul of the PDOs mapping (use fixed + non-fixed PDOs with the correct PDO entries) is required.

      This ticket should try to fix the 0x1702 as well.

        Attachments

          Issue Links

            Activity

            There are no comments yet on this issue.

              People

              Assignee:
              ttsai Te-Wei Tsai
              Reporter:
              ttsai Te-Wei Tsai
              Watchers:
              Te-Wei Tsai
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

                Dates

                Created:
                Updated:

                  Jenkins

                  No builds found.