Details
Description
It was discovered this week that the Portal Aspect was not, by default, recognizing the MOCs (Moc.fits files) included in the HiPS images generated by Eli Rykoff's new code stack.
This was traced to an overly strict interpretation of the FITS standard for the TFORMn keyword ("1K" was required when "K" should also have been accepted).
The request is to modify Firefly to accept plain "K" for the HEALPixel ID (as well as "J", though that won't be likely to be used in Rubin MOCs).
Requested to be included in a Firefly 2022.2.x bug-fix release in the near term.
Attachments
Issue Links
- relates to
-
DM-35874 Add RSP's own MOCs to the "featured MOC" list in DP0.2 deployment
- To Do
Deployed on data-int.lsst.cloud as part of a Portal/suit test build:
Git Commit: 70fc3b9
Firefly Git Commit: b9c2b39ec