Description
Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 (requirement document) since it is unpractical under this tight schedule (and we are replacing all the Harris software at this moment). Instead, this ticket is to consider a possible test plan and clarify the possible factors to do the judgement. This will consider the possible simulation test as well.
Note. Based on Doug, people believe the M1M3 actual mirror should be safe because the related support system passed all the requirements.
1. Compare the parameter files between the surrogate mirror and actual mirror.
2. Force --> Step --> Displacement under 0-90 degree
3. Check the AOS correction of M2 bending mode in um. Use the file of M2_1um_grid.yaml in ts_phosim.
Attachments
Issue Links
- is triggered by
-
DM-36663 Review the Harris Documents related to Mirror Test
- Done
Activity
Description | Draft the idea of M2 mirror safety test. | Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to insure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 since it is unpractical under this tight schedule. Instead, this ticket is to consider a test plan and study the possible factors to do the judgement. This will consider the possible simulation test before the test as well. |
Description | Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to insure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 since it is unpractical under this tight schedule. Instead, this ticket is to consider a test plan and study the possible factors to do the judgement. This will consider the possible simulation test before the test as well. | Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 since it is unpractical under this tight schedule. Instead, this ticket is to consider a test plan and study the possible factors to do the judgement. This will consider the possible simulation test before the test as well. |
Description | Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 since it is unpractical under this tight schedule. Instead, this ticket is to consider a test plan and study the possible factors to do the judgement. This will consider the possible simulation test before the test as well. |
Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 (requirement document) since it is unpractical under this tight schedule (and we are replacing all the Harris software at this moment). Instead, this ticket is to consider a possible test plan and clarify the possible factors to do the judgement. This will consider the possible simulation test as well.
Note. Based on Doug, people believe the M1M3 actual mirror should be safe because the related support system passed all the requirements. |
Description |
Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 (requirement document) since it is unpractical under this tight schedule (and we are replacing all the Harris software at this moment). Instead, this ticket is to consider a possible test plan and clarify the possible factors to do the judgement. This will consider the possible simulation test as well.
Note. Based on Doug, people believe the M1M3 actual mirror should be safe because the related support system passed all the requirements. |
Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 (requirement document) since it is unpractical under this tight schedule (and we are replacing all the Harris software at this moment). Instead, this ticket is to consider a possible test plan and clarify the possible factors to do the judgement. This will consider the possible simulation test as well.
Note. Based on Doug, people believe the M1M3 actual mirror should be safe because the related support system passed all the requirements. 1. Force --> Step --> Displacement under 0-90 degree 2. Check the AOS correction of M2 bending mode in um. Use the file of *M2_1um_grid.yaml* in *ts_phosim*. |
Description |
Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 (requirement document) since it is unpractical under this tight schedule (and we are replacing all the Harris software at this moment). Instead, this ticket is to consider a possible test plan and clarify the possible factors to do the judgement. This will consider the possible simulation test as well.
Note. Based on Doug, people believe the M1M3 actual mirror should be safe because the related support system passed all the requirements. 1. Force --> Step --> Displacement under 0-90 degree 2. Check the AOS correction of M2 bending mode in um. Use the file of *M2_1um_grid.yaml* in *ts_phosim*. |
Draft the idea of M2 mirror safety test. This task will just consider the minimum things we could do to ensure the mirror is safe when using the M2 cell control system. There is no intention to verify the LTS-107 (requirement document) since it is unpractical under this tight schedule (and we are replacing all the Harris software at this moment). Instead, this ticket is to consider a possible test plan and clarify the possible factors to do the judgement. This will consider the possible simulation test as well.
Note. Based on Doug, people believe the M1M3 actual mirror should be safe because the related support system passed all the requirements. 1. Compare the parameter files between the surrogate mirror and actual mirror. 2. Force --> Step --> Displacement under 0-90 degree 3. Check the AOS correction of M2 bending mode in um. Use the file of *M2_1um_grid.yaml* in *ts_phosim*. |
Watchers | Te-Wei Tsai [ Te-Wei Tsai ] | Pablo Zorzi, Te-Wei Tsai [ Pablo Zorzi, Te-Wei Tsai ] |
Status | To Do [ 10001 ] | In Progress [ 3 ] |
Story Points | 1 |
Story Points | 1 | 2 |
Story Points | 2 | 3 |
Reviewers | Pablo Zorzi [ pzorzi ] | |
Status | In Progress [ 3 ] | In Review [ 10004 ] |
Status | In Review [ 10004 ] | Reviewed [ 10101 ] |
Resolution | Done [ 10000 ] | |
Status | Reviewed [ 10101 ] | Done [ 10002 ] |