Uploaded image for project: 'Data Management'
  1. Data Management
  2. DM-39121

Fill values to forceActuatorInfo

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Done
    • Resolution: Done
    • Fix Version/s: None
    • Component/s: ts_main_telescope
    • Labels:

      Description

      Values for forceActuatorInfo (xDataReferenceId,..) aren't filled in. Fix that - create ForceActuatorInfo class and let it publish what's loaded from ForceActuatorSettings. or rename ForceActuatorSettings to ForceActuatorInfo (as it doesn't really hold extra values) and fill it from static data.

        Attachments

          Activity

          Hide
          pkubanek Petr Kubanek added a comment -
          Show
          pkubanek Petr Kubanek added a comment - Please see PRs: https://github.com/lsst-ts/ts_m1m3support/pull/136 - C (Dave) https://github.com/lsst-ts/ts_cRIOpy/pull/65 - Python (Te-Wei Tsai)
          Hide
          ttsai Te-Wei Tsai added a comment -

          Reviewed in GitHub.

          Show
          ttsai Te-Wei Tsai added a comment - Reviewed in GitHub.

            People

            Assignee:
            pkubanek Petr Kubanek
            Reporter:
            pkubanek Petr Kubanek
            Reviewers:
            Dave Mills, Te-Wei Tsai
            Watchers:
            Dave Mills, Petr Kubanek, Te-Wei Tsai
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Jenkins