      Description

      I think there is a bug in /Users/azuri/lsstsw/stack/DarwinX86/daf_butlerUtils/2016_01.0-4-g325729a+1/python/lsst/daf/butlerUtils/cameraMapper.py(858)_defectLookup():

      ccdKey, ccdVal = self._getCcdKeyVal(dataId)
      

      which assigns the CCD name (in my case 'r_2') to ccdVal, while obs_subaru/bin.src/genDefectFits.py and obs_subaru/bin.src/genDefectRegistry.py use the ccd ID (in my case '5') or serial number (5) to create the fits file containing the defects for each CCD. For HSC, the CCD name, ID, and serial are all the same, but it's causing trouble for PFS...