Details
-
Type:
Bug
-
Status: Won't Fix
-
Resolution: Done
-
Fix Version/s: None
-
Component/s: astrometry_net, meas_astrom
-
Labels:None
-
Epic Link:
-
Team:SQuaRE
Description
Running processCcd on monocam data segfaults during astrometry.
Steps to reproduce:
- Download attached datafile.
- conda install v12.1 of the stack
- setup ticket branch
DM-8401of obs_monocam -
ingestImages.py path/to/downloaded/file/2016-05-12CAblank5_y4_70.fits
-
processCcd.py filename --rerun test_1 --id visit=1333 --doraise -c isr.doLinearize=False isr.doBias=False isr.doDark=False isr.doFlat=False
Should see segfault after
processCcd.calibrate.astrometry.solver INFO: Number of selected sources for astrometry : 552
|
Interestingly, running processCcd with -c calibrate.doAstrometry=False results in the astrometric solver still being run, and a segfault still occurring, but in a different place. Just mentioning as this may or may not be useful debug info.